Single Phase Voltage Monitoring –

Voltage Type AC
Voltage (V) 220 – 240
Number of Poles 1 Pole + N
Application Single Phase Voltage Monitoring
Relay Output 1 x SPDT 32A direct, any current through contactors
Brand NOVATEK ELECTRO
Display Digital 3 x 7 segment LED display
Type Under voltage, Over voltage, Neutral break protection

9 in stock

Description

RN-113 single phase voltage monitoring relay is designed to de-energize an industrial/appliance single-phase 220V/50Hz load in case of inadmissible voltage variations in the mains with subsequent automatic re-energizing after the circuit parameters recovery. Load is connected to the relay either directly via relay terminals or through a magnetic starter, depending on the wattage.

The relay can operate in four independent modes:

  • Voltage monitoring relay
  • Minimum voltage monitoring relay
  • Maximum voltage monitoring relay
  • Time relay with a restart delay

The device front panel features load status indicator (on/off) and three-digit, seven-segment display, which displays (depending on the device status):

  • Actual RMS voltage
  • Accurate value of the set-up parameter
  • Time remaining till automatic load re-energizing
  • Emergency de-energizing the load (RMS voltage flashing)

The variable pot knobs on the front panel allow for setting:

  • The maximum allowable voltage tripping threshold
  • The minimum allowable voltage tripping threshold
  • Time delay for load re-energizing after the circuit parameters recovery

Additional Information:

  • Item Code: RN-113
  • Port of Dispatch: New Delhi

TECHNICAL CHARACTERISTICS

Rated voltage, V220 – 240
Rated voltage frequency, Hz48 – 52
Harmonical configuration (nonsinusoidality) of power supply voltageEN 50160:2010

Adjustment ranges:

– minimal voltage tripping range (Umin), V

– maximal voltage tripping range (Umax), V

– autoreclosing time delay (Ton), sec

170 – 230

240 – 290

5 –900

Fixed tripping time delay in case maximal voltage fault (Umax) detected, sec 1
Fixed tripping time delay in case minimal voltage fault (Umin) detected, sec12
Fixed tripping time delay in case of voltage decrease more than 50V than the adjusted minimal voltage tripping threshold (Umin), sec0.2
Fixed tripping time delay in case of voltage increase more than 30V than the adjusted maximal voltage tripping threshold (Umax), sec0.12
Maximal commutation current (active power load), A32
Tripping Voltage level accuracy, Vupto 3

Minimal operation voltage level at which RN-113 will keep working, V

Maximal operation voltage level at which RN-113 will keep working, V

100

420

Protection class against electric shock    II
Permissible contamination level    II
Overvoltage category    III
Nominal  voltage  of isolation, V   450
Voltage hysteresis, V (no less than)   4-5
Rated impulse withstand voltage, kV 4
Moment of an inhaling of screws of input  terminals plugs, N*m 0.4
Moment of an inhaling of screws of output  terminals plugs, N*m 0.5
Guide section of connecting plugs of input  terminals, mm2 0.3-3.3
Guide section of connecting plugs of output  terminals, mm2 0.65-5
Operational temperature range, °Сfrom -35 to + 55
Total power consumption, mA15

Device level protection:

  • front  panel
IP40
  • terminals
IP20

Commutation life of the output contacts:

– under 16A power load,  times (no less than)

– under 5A power load,  times (no less than) .

100 000

1 000 000

Outer dimensions, (3 S-modules) H*B*L,mm90 х 52.6 х 66.3
Weight, kg, no less than0.150
 

Mounting to standard 35mm DIN rail

Device allocation – control equipment and distribution

Specification of the Output contacts 1-2-3:
 Maximal current at ~ 250V ACMaximal power when contacts are closedMaximal commutation power

Maximal allowed

AC/DC Voltage

Maximal current

at 14V DC

Cos ф = 1.0

32 A7200 VA7200 VA250/110 V

30 А

No harmful substances in excess of the maximum permissible concentration is available.

RN-113 complies with requirements:

IEC 60947-1:2004; ІEC 60947-6-2:1992; CISPR 11:2004; IEC 61000-4-2:2001.

Additional information

Weight 0.25 kg
Size

Three pole MCB size (W:52 x H:90 x D:68.5 mm)

Color

White